Control Interface Module In The Smart Line Module Chassis Format - Siemens SINAMICS S120 Commissioning Manual

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Diagnostics
5.2 Diagnostics using LEDs
5.2.2.9

Control Interface Module in the Smart Line Module chassis format

Table 5- 14
Meaning of the LEDs "READY" and "DC LINK" on the Control Interface Module in the Smart Line Module
LED, state
READY
DC LINK
Off
Off
Green
Off
Orange
Red
Orange
Orange
Red
---
Flashing
---
light
0.5 Hz:
Green / red
Flashing
---
light
2 Hz:
Green / red
Flashing
---
light
2 Hz:
Green /
orange
or
red / orange
Table 5- 15
Meaning of the LED "POWER OK" on the Control Interface Module in the Smart Line Module
LED
Color
POWER OK
Green
318
Description
The electronic power supply is missing or lies outside the permissible tolerance range.
The component is ready for operation and cyclic DRIVE-CLiQ communication is taking
place.
The component is ready for operation and cyclic DRIVE-CLiQ communication is taking
place.
The DC link voltage is present.
The component is ready for operation and cyclic DRIVE-CLiQ communication is taking
place.
The DC link voltage is too high.
DRIVE-CLiQ communication is being established.
At least one fault is present in this component.
Note:
LED is activated irrespective of any reconfiguring of the corresponding messages.
Firmware is being downloaded.
Firmware download is complete. Wait for POWER ON.
Component detection using LED is activated (p0124).
Note:
Both options depend on the LED state when module recognition is activated via p0124 = 1.
State
Description
Off
DC link voltage < 100 V and voltage at -X9:1/2 less than 12 V.
On
The component is ready for operation.
Flashing
There is a fault. If the LED continues to flash after you have performed a
light
POWER ON, please contact your Siemens service center.