Siemens SINAMICS S120 Commissioning Manual page 331

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

The following table lists the possible icon colors with their significance. For more information
on this topic, refer to the online help in the TIA Portal, which you can call up using the icon
tooltips.
Display messages
Proceed as follows to display messages, which are assigned to an icon:
1. Double click the icon.
The "Display message" tab is moved into the foreground of the Inspector window.
All pending messages are displayed there.
Errors in the DRIVE-CLiQ connections of the drive lineup
All DRIVE-CLiQ components of the drive lineup are displayed in the device view. If the
DRIVE-CLiQ connections of the offline configuration differ from the actual wiring, then these
errors are displayed in the device view. The DRIVE-CLiQ connections are aligned online
(reference-actual).
If you call the tooltip of an incorrectly interconnected port, then you are provided with a
description of the error cause (reference-actual alignment). You must either change the
connections (wiring) at the device, or in the device view.
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
Icon
Meaning
OK = no fault active or maintenance is required
Maintenance is required
Maintenance is required for a subordinate component
Maintenance request
Maintenance request for a subordinate component
Fault/error
Fault/error on a subordinate component
Connection error to the device
Connection establishment
Diagnostic status is determined
Diagnostics
5.3 Diagnostics via Startdrive
331