Siemens SINAMICS S120 Commissioning Manual page 300

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Commissioning
4.11 Configuring brake control
4. Click "Status word". A mask with the same name opens.
Connect the signal sources for the following areas:
– Sequence control status word (r0899)
– Motor holding brake status word (r1229)
5. Click "Logic operations" in the "Brake control" mask.
The "Brake logic operations" dialog opens.
Figure 4-123 Extended brake control: Set logic operations
– Interconnect the signal sink for "OR operation" or for "AND operations".
– Click "OK" to confirm the settings and so close the dialog.