Setting the calculation of the controller data
1. Select one of the following options for the calculation of the controller data in the
"Calculation controller data" (p0340) drop-down list:
– No calculation
– Complete calculation
– Calculation without equivalent circuit diagram data
2. After the calculation type has been set (exception: "No calculation"), you can confirm the
calculation if this has not been done already (red status symbol).
To do this, click the "Confirm calculation" button.
The "Technology application" option is then disabled for the drive functions and the set
application can no longer be changed. The disable can be cancelled via the "Enable"
button. However, the calculation type must then be confirmed again.
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
The motor data is not calculated. This is the default setting.
The equivalent circuit diagram data is also calculated using the motor data.
The equivalent circuit diagram data entered during the parameter assignment of the
motor is not changed. The equivalent circuit diagram data is not calculated.
4.7 Basic parameterization of the drive objects