Commissioning
4.4 Creating a project offline in Startdrive
3. Drag the unspecified Motor Module into the device view.
Figure 4-19
The DRIVE-CLiQ connection is automatically established.
4. Click the Motor Module in the device view. Ensure that you click in the white area of the
Motor Module.
5. Open the Inspector window if it has still not been opened or displayed.
104
Motor Module inserted
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1