Commissioning
4.8 Loading the project to the target device
3. Check the messages in the "Load preview" dialog. Activate the required actions in the
"Action" column to perform a secure download.
Figure 4-88
As soon as downloading becomes possible, the "Load" button is enabled.
4. Click "Load".
The loading operation is performed. If there is a need for synchronization, the system
automatically displays the "Synchronization" dialog. This dialog displays messages and
suggests actions that are needed for the synchronization. You have the option of
performing these actions or forcing the download without synchronization by clicking
"Force download to device". If you have performed the suggested actions, you will be
asked whether you want to continue with the download. The "Load results" dialog then
opens. In this dialog, you can check whether the load task was successful and select any
further actions.
5. Click "Finish".
Result
The selected project data has been downloaded to the drive units.
Note
Upload from device
Conversely, the project data of a selected drive unit can also be uploaded into your
Startdrive project on your PC. Proceed as described in Chapter "Loading project data from a
drive unit (Page 74)" for this purpose.