Interfaces

4.10 Power Module Interface

Note
The test sockets are provided as a support to commissioning and diagnostics; they must not be
connected for normal operation.
4.10
Power Module Interface
SIMOTION D410-2 can be connected to a SINAMICS Power Module in blocksize format via the
Power Module interface.
Power Modules PM340 and PM240‑2 (PM240‑2 as of SIMOTION V4.4/SINAMICS V4.7) can be
used.
Figure 4-10
Note
SIMOTION D410-2 can only be connected to a SINAMICS Power Module in blocksize format via
the Power Module interface. A Power Module in chassis format must be connected via the
DRIVE‑CLiQ interface (see SIMOTION D410-2 Commissioning and Hardware Installation
Manual).
A SIMOTION D410-2 cannot be operated with SINAMICS G120 (PM2x0) Power Modules.
Booksize Motor Modules can likewise not be connected.
80
SIMOTION D410-2 interface to the Power Module interface (PM-IF)
SIMOTION D410-2
Equipment Manual, 07/2021, A5E33446720B