1.10.1 Replacement of the device fan for sizes FS4 and FS5 (IP20)

With the DA1 frequency inverters in sizes FS4 and FS5, the installed device
fan can be replaced.
The fan is inserted and can be removed from the bottom of the device.
In frame size FS4
Remove the fan cover (①, ②).
1
2
Figure 23: Remove fan cover
Release the plug connection (③, ④) and slide out the fan (⑤, ⑥).
3
4
5
Figure 24: Release the plug connection
DA1 Variable Frequency Drives 08/18 MN04020005Z-EN www.eaton.com
1.10 Maintenance and inspection
1
6
5
1 DA1 device series
39