3 Installation
3.3 Assembly
82
Table 5: Minimum clearances and required cooling airflow
Frame size
a
(protection)
mm
in
FS2 (IP20)
50
1.97
FS2 (IP66)
0
0
FS3 (IP20)
50
1.97
FS3 (IP66)
0
0
FS4 (IP20)
25
0.98
FS4 (IP55)
10
0.39
FS5 (IP20)
25
0.98
FS5 (IP55)
10
0.39
FS6 (IP55)
10
0.39
FS7 (IP55)
10
0.39
FS8 (IP20)
50
1.97
The values in table5 are recommended values for an ambient air temperature
of +50 °C for IP20 and +40 °C for IP55 and +40 °C in frame size FS8 (IP20),
an installation altitude of up to 1000 m and a switching frequency of up to
8 kHz.
→
Typicalheat loss makes up about 3 % of the operational load
conditions.
Frame size
FS2, ..., FS7
FS8
Figure 45: Minimum required clearance ① in front of the
①
→
Please ensure that the installation makes it possible to properly
open and close the control signal terminal enclosure.
DA1 Variable Frequency Drives 08/18 MN04020005Z-EN www.eaton.com
b
c
mm
in
mm
in
31
1.22
75
2.95
12
0.47
150
5.91
31
1.22
100
3.94
13
0.51
150
5.91
70
2.76
200
7.87
71
2.8
200
7.87
70
2.76
200
7.87
70
2.76
200
7.87
140
5.52
200
7.87
140
5.52
200
7.87
162
6.38
350
13.78
Minimum clearance ①
≧ 15 mm (≧ 0.59 in)
≧ 50 mm (≧ 1.97 in)
variable frequency drive when installed in an
enclosure (control panel)
Required airflow
3
m
/h
cfm
70
41
0
0
190
112
0
0
105
62
425
250
177
104
425
250
650
383
650
383
825
485