5 Error messages
5.1 Introduction
142
Message
Error no.
42
AtF-03
43
AtF-04
44
AtF-05
49
OVt-Ph
50
Sc-FO1
51
Sc-FO2
52
Sc-FO3
53
Sc-F04
60
OF-01
61
OF-02
70
PLC-01
71
PLC-02
72
PLC-03
73
PLC-04
74
PLC-05
DA1 Variable Frequency Drives 08/18 MN04020005Z-EN www.eaton.com
Possible cause and remedy
Motor identification failed:
The measured motor inductance is too low.
• Make sure that the motor is connected properly and working correctly.
Motor identification failed:
The measured motor inductance is too high.
• Make sure that the motor is connected properly and working correctly.
• Check to make sure that the device's rated output matches the motor's
rated output. The difference should not exceed one full output class.
Motor identification failed:
The measured motor parameters do not match.
• Make sure that the motor is connected properly and working correctly.
• Check to make sure that the device's rated output matches the motor's
rated output. The difference should not exceed one full output class.
A phase in the motor cable is not connected or is broken.
No valid Modbus frame was received within the time specified in P5-06.
• Check to make sure that the network master is working correctly.
• Check connecting cables.
• Increase the value of P5-06 to an acceptable value.
No valid CANopen frame was received within the time specified in P5-05.
• Check to make sure that the network master is working correctly.
• Check connecting cables.
• Increase the value of P5-05 to an acceptable value.
Communications between the device and the plugged-in field bus option have
dropped out.
• Check to make sure that the module is installed properly.
Communications between the device and the plugged-in I/O expansion have
dropped out.
• Check to make sure that the module is installed properly.
No internal connection to an optional card
Optional module in undefined operating state
Non-supported function block from function block editor
Program from function block editor is too big
Division by zero
Lower limit is higher than upper limit
Overflow table Function block editor