Eaton PowerXL DA1 Series Installation Manual page 105

Variabe frequency drives
Hide thumbs Also See for PowerXL DA1 Series:
Table of Contents

Advertisement

3.6.1.2 Connection for frame sizes FS4 to FS7 with IP55
On enclosures with IP55 protection (frame sizes FS4 to FS7), the connection
area will be located behind the lower enclosure cover.
Sizes FS4 and FS5
2
1
5.8 x 1 mm
2 Nm (17.7 lb-in)
Figure 62: Removing the cover
Release the latches by turning them counterclockwise (90 degrees) so that
they are in a vertical position [1] and lift the cover off forwards [2].
Sizes FS6 and FS7
3
2
Figure 63: Removing the cover
Unscrew the two screws at the bottom [1], lift the cover from the bottom [2],
and then remove it forwards
DA1 Variable Frequency Drives 08/18 MN04020005Z-EN www.eaton.com
1
PZ 2
2 Nm (17.7 lb-in)
3 Installation
3.6 Electrical Installation
101