3 Installation
3.7 Block diagrams
3.7.4 DA1-...-B6SC
1 ~
3 ~
L1/L
L2/N
PWR
DC-
DC+
BR
U
V
M
3 ~
126
Type
DA1-12-...-B6SC
DA1-32-...-B6SC
DA1-34-...-B6SC
DA1-35-...-B6SC
PE
L3
12
13
EMC
VAR
STO
W
PES
Figure 93: DA1-...-B6SC block diagram
① Direct enable of the STO function or relay: Safe Torque Off (STO),
SIL 2 (EN 61800-5-2) as in → figure 91, page 124
② The RFI filter is not contained in the DA1-35-...-B6XC device.
The STO connection must be made by the user.
DA1 Variable Frequency Drives 08/18 MN04020005Z-EN www.eaton.com
Mains
Voltage U
LN
1~ 200 V (-10%) - 240 V (+10%)
3~ 200 V (-10%) - 240 V (+10%)
3~ 380 V (-10%) - 480 V (+10%)
3~ 500 V (-10%) - 600 V (+10%)
REV
OFF
FWD
1
2
3
14
15
16
17
Motor
Frequency f
Voltage U
LN
2
50/60 Hz
3~ 230 V
50/60 Hz
3~ 230 V
50/60 Hz
3~ 400 V/ 460 V 0 - 500 Hz
50/60 Hz
3~ 500 V/ 575 V 0 - 500 Hz
4
10
5
6
CPU
18
11
8
Frequency f
2
0 - 500 Hz
0 - 500 Hz
7
X1
RS485
Modbus RTU
CANopen
OP-Bus
9

Advertisement