6 Specifications
6.2 Specific rated operational data
6.2.3 DA1-34... series
Size
Rated operational current
Overload current for 60 s every 600 s
Apparent power at rated operation
Rated motor output
Power input side (primary side):
Number of phases
Rated voltage
Input current (phase current)
Minimum braking resistor
Switching frequency (pulse frequency)
Factory default setting
Settings range
Maximum leakage current to earth (PE),
without motor
Efficiency
Heat dissipation at I
e
Frame size
152
Symbol
Unit
I
A
e
I
A
L
400 V
S
kVA
480 V
S
kVA
400 V
P
kW
460 V
P
HP
U
V
LN
I
A
LN
R
Ω
B
f
kHz
PWM
f
kHz
PWM
I
mA
PE
η
P
W
V
DA1 Variable Frequency Drives 08/18 MN04020005Z-EN www.eaton.com
2D2
4D1
5D8
2.2
4.1
5.8
3.3
6.15
8.7
1.52
2.84
4.02
1.83
3.41
4.8
0.75
1.5
2.2
1
2
3
three-phase
380 V - 10 % - 480 V +10 %, 50/60 Hz
(342 - 528 V ±0 %, 48 - 62 Hz ±0 %)
2.4
5.1
7.5
400
200
150
8
8
8
4 - 32
4 - 32
4 - 32
4.65
4.65
4.65
0.92
0.95
0.95
63.75
76.5
101.2
FS2
FS2
FS2
9D5
014
018
9.5
14
18
14.25
21
27
6.58
9.7
12.5
7.9
11.6
15
4.0
5.5
7.5
5
7.5
10
11.2
19
22
100
75
50
8
8
8
4 - 32
4 -24
4 - 24
4.65
1.55
1.55
0.96
0.96
0.97
136
209
300
FS2
FS3
FS3
024
24
36
16.6
20
11
15
28.9
40
8
4 - 16
1.55
0.97
297
FS3