Connection Instructions Fipio/Telemecanique - Festo FB16 Electronic Manual

Valve terminal type 03/05, field bus connection
Table of Contents

Advertisement

VIFB16 - 03/05
Valve
terminal - Pin
assignment
D1+ / D2+
1 S+
3 S-
D1- / D2-
4 Screening
= Trunk cable
= Drop cable
ACC4
= TAP junction
Fig. 3/17: Notes on connection FIPIO/Telemecanique
0506b
3. Installation
Connection instructions
FIPIO/Telemecanique
PLEASE NOTE
Always check the pin assignment of the
module in the PLC manual for your controller.
Connection per branch cable
(Drop cable)
1
ACC4
2
valve
terminal
D2+
D2-
D1+
D1-
Screen
braid
TSX FP CA xxx
TSX FP CC xxx
TSX FP ACC4
Example TAP ACC4
1
1
2
_
_
+
+
T1
T2
D2
D1
_
_
+
+
1
3-31

Advertisement

Table of Contents
loading