VIFB16 - 03/05
Fastening
screws
max. 1 Nm
Fig. 2/2: Fitting the end plates (Example for terminal type 03)
0506b
2. Fitting
Earth the end plates as follows:
Right-hand end plate (type 03):
In order to earth the right-hand end plate,
connect the fitted cable on the inside to the
appropriate contacts on the pneumatic modu-
les or on the node (see diagram below).
Left-hand end plate (types 03 and 05):
Connect the left-hand end plate conductively
to the other components via the spring
contacts which are already fitted.
Instructions on grounding the complete valve
terminal are to be found in the chapter "Installa-
tion".
The following diagram shows how both end
plates are fitted.