Fig. 3/6: Setting "HOLD/STOP"
0506b
3. Installation

Setting "HOLD/STOP"

(error reaction of the outputs)

The reaction of the outputs to an error (transmis-
sion error on the FIPIO-field bus or interruption
in the field bus cable) can be set as follows:
DIL switch 1
OFF
(STOP mode)
ON
(HOLD mode)
DIL-Switch
Error reaction
All outputs will be switched off if
there is an error (valves and
electrical outputs).
All outputs retain their current
status if there is an error (valves
and electrical outputs).
Error reaction of outputs
*)
STOP
HOLD
*) Factory setting