2.3 TYPE 05: FITTING THE VALVE TERMINAL
2-12
2. Fitting

Wall fitting (type 05)

WARNING
With long terminals (e.g. several I/O modules)
use additional supporting brackets every
200 mm. This is to avoid the following:
overloading the fastening eyes on the
left-hand end plate
the terminal sagging
natural resonances
Proceed as follows:
Calculate the weigh of the terminal
(weigh or estimate).
General rule:
Sub-base *)
- 4 valve locations
incl. valves
- 8 valve locations
incl. valves
- 12 valve locations
incl. valves
per node
per electronic module
*) Components for vertical stacking:
Please see pneumatics manual P.BE-ISO-GB
for weights.
Make sure that the fastening surface can
carry this weight.
ISO size 1
ISO size 2
8 kg
12 kg
14 kg
20 kg
20 kg
28 kg
1 kg
1 kg
0.4 kg
0.4 kg