VIFB16 - 03/05
2-10
2. Fitting
Hat rail fitting (type 03)
The terminal is suitable for fitting onto a hat rail
(support rail as per EN 50022). For this purpose
there is a guide groove on the rear of all
modules for hanging the terminal on the hat rail.
CAUTION
•
Fasten the valve terminal onto the hat rail
with the hat rail clamping unit.
•
If the terminal is fitted in a sloping position
or at a point subjected to vibration, use
screw (7) to protect the hat rail clamping unit
against unintentional loosening/opening.
PLEASE NOTE
•
If fitted in a horizontal position and with a
non-vibrating load the hat rail clamping unit
need not to be fastened with screws (7).
•
If there is no hat rail clamping unit on the
terminal, it can be ordered and fitted at a
later stage.
The use of MIDI or MAXI clamping units
depends on the end plate fitted (MIDI/MAXI).
Proceed as follows:
•
Calculate the weight of the terminal (weigh or
estimate). General rule:
per pneumatic module
per node
per electronic module
MIDI
MAXI
800 g
1200 g
1000 g
1000 g
400 g
400 g
0506b