Wall Fitting (Type 03); Type 03 Fitting The Valve Terminal - Festo FB16 Electronic Manual

Valve terminal type 03/05, field bus connection
Table of Contents

Advertisement

VIFB16 - 03/05
2.2 TYPE 03: FITTING THE VALVE TERMINAL
7.6 mm
M6
Fig. 2/4: Fitting terminal type 03 onto a wall
0506b
2. Fitting

Wall fitting (type 03)

WARNING
With long terminals use additional supporting
brackets every 200 mm. This is to avoid the
following:
overloading the fastening eyes on the
left-hand end plate
the terminal sagging
natural resonances
Proceed as follows:
Calculate the weight of the terminal (weigh or
estimate). General rule:
per pneumatic module
per node
per electronic module
Make sure that the fastening surface can car-
ry this weight.
Fasten the terminal with four M6 screws as
shown below (fitting position as desired). Use
washers if necessary.
MIDI
MAXI
800 g
1200 g
1000 g
1000 g
400 g
400 g
2-9