Type 05 Connecting The Operating Voltages - Festo FB16 Electronic Manual

Valve terminal type 03/05, field bus connection
Table of Contents

Advertisement

VIFB16 - 03/05
3.2.2 Type 05: Connecting the operating voltages
0506b
3. Installation
WARNING
Use only PELV circuits as per IEC/DIN EN
60204-1
(Protective
PELV) for the electrical supply.
Consider also the general requirements for
PELV circuits in accordance with IEC/DIN EN
60204-1.
Use power supplies which guarantee reliable
electrical isolation of the operating voltage as
per IEC/DIN EN 60204-1.
By the use of PELV circuits, protection against
electric shock (protection against direct and
indirect contact) is guaranteed in accordance
with IEC/EN 60204-1. (Electrical equipment for
machines, General requirements).
CAUTION
The power supply to the outputs/valves (pin 2)
must be separately fused externally with max.
10 A. The external fuse prevents the valve ter-
minal from being damaged in the event of a
short circuit.
Extra-Low
Voltage,
3-21

Advertisement

Table of Contents
loading

Table of Contents