VIFB16 - 03/05
Addresses
Assignment of the output table of a valve terminal
of the table
2
%MW n (0..7)
%MW 1200
15
%MW 1201
%MW 1202
%MW 1203
%MW 1204
Reserved (not used by the valve terminal)
%MW 1205
%MW 1206
%MW 1207
Please note:
Valves:
Digital outputs:
These fields contain the current status (logic 0 or 1), with which the physically
existing valves/digital outputs are controlled.
*)
Due to the 4-bit orientated addressing of the valve terminal, the addresses
14 and 15 cannot be used ("rounded," see chapter 4.1).
Fig. 4/22: Example 1 – concrete assignment of the outputs of a
valve terminal
0506b
4. Commissioning
Addressing example
The following illustrations show as an example
the concrete addressing of the valve terminal
fitted in the standard manner from chapter 4.1.
The following assumptions have been made:
I/O tables, fixed in the configuration editor:
•
Output tabulation words: %MW1200(0..7)
•
Input tabulation words: %MW1210(0..7)
The field bus address set on the valve terminal
is not relevant in this example, because in the
entries (symbols of the I/O tables) in the
configuration editor, both %MW tables have
been assigned explicitly to one valve terminal
(with its defined field bus address).
15
14
13
12
2
2
2
*)
*)
14
13
12
fields 0 ... 13;
fields 16 ... 23
11
10
9
8
2
2
2
2
2
11
10
9
8
7
23 22 21 20 19 18 17 16
7
6
5
4
3
2
2
2
2
2
6
5
4
3
2
2
1
0
2
2
1
0
4-51