Electronic Input Modules; Electronic Output Modules - Festo FB16 Electronic Manual

Valve terminal type 03/05, field bus connection
Table of Contents

Advertisement

VIFB16 - 03/05
0506b
Appendix A
Electronic input modules (PNP/NPN)
Input voltage range
Logic level PNP
• ON
• OFF
Logic level NPN
• ON
• OFF
Current consumption
(at 24 V or 0 V) (current
from sensor to input at
logic 1)
Response delay (at 24 V)
Common fuse for operating
voltage supply to sensors
Electrical isolation
Electronic output modules (PNP)
Loading
• per digital output
Current consumption
(at 24 V)
• Internal consumption at
logic 1
Electronic fuse
(short circuit overload)
• Trigger current
• Response time
(short circuit)
Electrical isolation
DC 0 ... 30 V
≥ 12.5 V
≤ 7 V
≤ 5 V
≥ 11 V
max. 9 mA
typ. 5 ms
2 A, slow blowing
None
max. 0.5 A (Bulbs max.
10 W because of PCT
resistor characteristics)
typ. 9 mA
max. 1.5 A
max. 1 s
None
A-5