Festo FB16 Electronic Manual page 127

Valve terminal type 03/05, field bus connection
Table of Contents

Advertisement

VIFB16 - 03/05
0506b
4. Commissioning
The menu items have the following meanings:
Connection point:
Non-modifiable information field which conta-
ins the FIPIO address of the valve terminal
between 1 and 62.
Composition of the equipment:
Non-modifiable information field which conta-
ins the device reference FSD_C8 of the valve
terminal.
Comment:
Comment entry line. This text is later visible
e.g. in the dynamic display. Here you can
enter, in particular, the device names (e.g.
Festo valve terminal) belonging to the device
reference.
Input tabulation - Fault:
Error word of the input tables. This shows
whether the inputs formed under "Input
tabulation - Words" are suitable for further
processing ("validity of the inputs"). The
variable to be entered is of type %MW. The
evaluation of these variables is given
at the end of this chapter.
4-45