5. Diagnosis CPV−CS02 (ABB CS31)
LED
Colour
PS
green
lights up
PL
green
lights up
off
BF
P
off
Tab. 5/1:
Normal operating status
5.1.2 Fault diagnosis with the LEDs
LED
Colour
PS
off
PS
green
flashes slowly
PS
green
lights up
Tab. 5/2:
Fault diagnosis with the green LED PS
5−4
Operating status
Power supply for the electronics/
sensors OK
Power supply for the valves/
outputs OK
No bus fault
No other fault
Fault diagnosis with the LED PS
The green LED PS (Power System") indicates faults in the
operating voltage supply.
Operating status
Operating voltage for electronics
not applied
Operating voltage for the
electronics . 18 V
Operating voltage for the
electronics is applied
Fault treatment
Fault treatment
Check operating voltage supply
·
(pin 1)
Festo P.BE−CPV−DI02−E N en 0704NH