2. Commissioning CPV−DI02 (PROFIBUS−DP)

2.1.3 Address assignment of CPI/CP modules

CPI/CP modules
Type
CPI/CP input modules
CPI/CP output modules
CP valve terminals
1)
with extended functions
2)
without extended functions
Further CPI modules and CPI−capable valve terminals in preparation.
Tab. 2/1:
Assigned I/Os of the CPI/CP modules
2−6
Tab. 2/1 provides an overview of the assigned addresses for
the various CPI/CP modules (as at autumn 2007).
CP−E08−M8−CL
CP−E08−M12−CL
CP−E16−KL−CL
CP−E16−M8
CP−E16N−M8
CP−E16−M8−Z
CP−E16−M12x2−5POL
CP−E16N−M12x2
CP−E16−KL−IP20−Z
CP−A04−M12−CL
CP−A08−M12−5POL
CP−A08N−M12
CPV...−CPI
CPV−SC−CPI
CPV...−GE−FB−4
CPV...−GE−FB−6
CPV...−GE−FB−8
CPA10/14−IFB−CP
Assigned I/Os on...
CPI−
CPI masters
1)
1)
capable
capable
I
Yes
8 I
Yes
8 I
Yes
16 I
No
16 I
No
16 I
No
16 I
No
16 I
No
16 I
No
16 I
Yes
No
No
Yes
Yes
No
No
No
No
Festo P.BE−CPV−DI02−EN en 0704NH
1)
2)
CP masters
O
I
O
16 I
16 I
16 I
16 I
16 I
16 I
16 I
16 I
16 I
8 O
16 O
16 O
16 O
16 O
16 O
16 O
16 O
16 O
16 O
16 O
16 O
16 O
16 O
16 O
16 O
16 O
16 O

Hide quick links: