3. Diagnosis CPV−DI02 (PROFIBUS−DP)
Options
Set all the outputs of the output module to
·
logical 0 (RESET)
logical 0" (RESET)
Briefly interrupt the CP connection at the
·
CP output module or
CP output module or
Interrupt briefly the operating voltage for the
·
CPI system
Tab. 3/20: Deleting the fault possibilities
Festo P.BE−CPV−DI02−E N en 0704NH
Deleting faults
You can quit the fault by resetting all 8 outputs. You can do
this in one of the following ways:
Explanation
The outputs can then be used again. If the short circuit/over
load still exists, the outputs will be switched off again.
Manually or automatically in the program
Outputs on the output module will be reset
automatically
automatically
All outputs on the CPI system will be reset
automatically
3−27