1. Installation CPV−DI02 and CPV−CS02
1
Cable
2
Strain relief
3
Housing
4
Connecting part
Fig. 1/8: Individual socket parts and cable routing
Preparing
1−26
1
4
When you have selected suitable cables, connect them as
follows (Fig. 1/8):
1. Open the socket: Loosen the centre knurled nut.
2. Open the strain relief on the rear of the housing. Pass the
cable through.
3. Remove 5 mm of the insulation from the end of the cable
and fit core end sleeves.
4. Connect the conductors.
5. Replace the connecting part on the housing of the socket
and screw it tight. Pull the cable back so that there are no
loops inside the housing.
6. Tighten the strain relief.