Technical Appendix; Technical Specifications; Common Technical Specifications Of Cpv−Di02 And Cpv−Cs02 - Festo CPV-D102 Elektronics Manual

With field bus direct connection
Table of Contents

Advertisement

A. Technical appendix
A.1

Technical specifications

A.1.1 Common technical specifications of CPV−DI02 and CPV−CS02
General information
Temperature range
operation
storage/transport
Relative air humidity
Protection class as per EN 60529 plug connector
inserted or provided with protective cap
Protection against electric shock
(protection against direct and indirect contact
as per IEC/DIN EN 60204−1)
Electromagnetic compatibility
EMC interference emission
EMC resistance to interference
Vibration and shock
vibration
shock
Valves
*)
The CP system is intended for industrial usage.
Festo P.BE−CPV−DI02−EN en 0704NH
−5
+50 °C
−20
+70 °C
95 %, non−condensing
IP65
by means of a PELV circuit
(Protected Extra−Low Voltage)
see declaration of conformity
è www.festo.com
tested as per DIN/IEC 68/EN 60068 part 2−6;
for wall mounting:
0.35 mm path at 10
5 g acceleration at 60
tested as per DIN/IEC 68/EN 60068 part 2−27;
for wall mounting:
±30 g at 11 ms duration;
15 cycles
see Pneumatics manual type P.BE−CPV−...
60 Hz,
150 Hz
A−3