4. Commissioning CPV−CS02 (ABB CS31)

4.1.2 Address assignment of the CPV Direct

4−4
The CPV Direct always occupies 16 output addresses, irre
spective of the number of valve solenoid coils fitted on it.
This enables the CPV Direct to be extended at a later stage
without the need to shift the addresses.
The following diagram shows the addressing sequence of the
individual CPV valve plates.
4−5
0−1
2−3
6−7
Fig. 4/1: Address assignment of the CPV Direct
A valve location on the CPV Direct always occupies 2 ad
dresses, even if it is fitted with a blanking plate or pressure−
separator plate. If a valve location is fitted with a double−
solenoid valve, the following applies:
pilot solenoid 14 occupies the lower−value address;
pilot solenoid 12 occupies the higher−value address.
With single−solenoid valves the higher−value address
remains unused.
8−9
12−13
14−15
10−11
Festo P.BE−CPV−DI02−EN en 0704NH