Table of Contents

Advertisement

3. Diagnosis CPV−DI02 (PROFIBUS−DP)
Octet 2: Station status_2
Bit
Meaning
0
Diag.Prm_Req
1
Diag.Stat_Diag
2
3
Diag.WD_On
4
Diag.Freeze_Mode
5
Diag.Sync_Mode
6
7
Diag.Deactivated
bold = valve terminal related bits
Tab. 3/9:
Diagnostic bits of station status 2
Octet 3: Station status_3
Bit
Meaning
0
6
7
Diag.Ext_Diag_Overflow
Tab. 3/10: Diagnostic bits of station status 3
3−14
Explanation
1 = The master must configure the CPI system again
1 = The master must request diagnostic data until this
bit is set to 0
always 1 (set by CPI system)
1 = Response monitoring/watchdog activated
1 = FREEZE activated
1 = SYNC activated
reserved
always 0 (set by CPI system)
Explanation
reserved
always 0 (set by CPI system)
Festo P.BE−CPV−DI02−E N en 0704NH