3. Diagnosis CPV−DI02 (PROFIBUS−DP)

3.2.2 Diagnosis steps

3−10
The CP system offers extensive diagnostic possibilities via the
PROFIBUS−DP. The diagram below shows you the steps re
quired for diagnosing the CPI system. Only the diagnostic
bits, which require a further diagnostic step, are represented.
Note
The diagnostic information is only sent to the master if the
device−related diagnosis is activated (DIL switch element 8
at ON", see section 1.2.3).
7
6
5
4
3
Fig. 3/2: First diagnostic step
2
1
0
Bit
1
1
Station status 1
CPV Direct is without power or
the bus plug is not inserted.
The configuration of the
modules (see section 2.3) for
the CPI extension string does
not correspond to the
configuration saved in the
CPV Direct (see SAVE button
in sections 1.2.4 and 1.6).