Xerox WorkCentre Pro 423 Service Manual page 93

Hide thumbs Also See for WorkCentre Pro 423:
Table of Contents

Advertisement

Chain-
Description
Link
050-111
Slide the Finisher to the
right.
1. Slide the upper right unit
of the main unit, and
remove the jammed paper.
2. Close the unit.
Return the Finisher to the
original position.
050-112
Slide the Finisher to the
right.
1. Open Cover 4 and 5 of
the Finisher and remove the
jammed paper.
2. Close Cover 4 and 5.
Return the Finisher to the
original position.
050-113
Move the Finisher, open
Cover 4 of the Finisher, and
remove the jammed paper.
050-114
Slide the Finisher to the
right.
1. Open Cover 3 and 4 of
the Finisher and remove the
jammed paper.
2. Close Cover 3 and 4.
Return the Finisher to the
original position.
050-115
Slide the Finisher to the
right
1. Open Cover 5 of the
Finisher and remove the
jammed paper.
2. Close Cover 5.
Return the Finisher to the
original position.
081-311
Critical error in Fax
(N9-58)
controller
FAXC_ESysInFatalErr /
Fatal Error
WorkCentre Pro 423/428
LCD display
Job log
Corrective Action
Ready to print
(***-***)
Chain-
Description
Link
081-701
Invalid Fax number
FAXC_EInvalidCallNo /
Argument Error
081-702
Invalid Fax communication
parameter
FAXC_EInvalidParam /
Argument Error
081-703
MF-SYS memory full
FAXC_EmemFull / Memory
Error
081-704
Suspended by user
FAXC_EReqStoppedByFU /
State Error
081-705
Processing rejected due to
MF-SYS error
FAXC_EReqAbortedByFU /
Request Error
081-706
MF API call error of
unknown cause
FAXC_ESysInErr / Internal
Erro
081-707
Error of unknown cause in
MF API
FAXC_EUnknownErr /
Internal Error
081-708
Line disconnection from
remote station
FAXC_ERTDisconnectedLi
ne / Remote Error
081-709
Communication error of
unknown cause
FAXC_ECommunErrToRT /
Remote Error
081-710
Remote machine fault or
ISDN line error
FAXC_ERTObstacleOrLine
Err / Remote Error
03/02
2-61
LCD display
Job log
Corrective Action
Error resolved
Fax number
(***-***)
error
Error resolved
Fax
(***-***)
communicati
on
parameter
error
Error resolved
MF module
(***-***)
memory
shortage
Error resolved
User
(***-***)
suspension
Error resolved
Request
(***-***)
rejection due
to MF
module error
Error resolved
Unknown
(***-***)
error
Error resolved
Unknown
(***-***)
internal error
Error resolved
Remote
(***-***)
disconnectio
n
Error resolved
Unknown
(***-***)
communicati
on error
Error resolved
Remote
(***-***)
machine/ISD
N line fault
2.3 Level 2 Troubleshooting