Xerox WorkCentre Pro 423 Service Manual page 52

Hide thumbs Also See for WorkCentre Pro 423:
Table of Contents

Advertisement

WorkCentre Pro 423/428
V Code
Internal
Description
code
V6-06
825D
Invalid open type when file
is closed
V7-00
8501
0FFh fetched
V7-00
8502
Undefined instruction
executed.
V7-00
8503
Busy state not released
within specified time by
PUTCOM macro
V7-00
8504
Undefined PID received
V7-00
8505
Necessary PID not present
or PI data not correct
V7-00
8506
Unexpected CID received
V7-00
8507
Command acquired by
GETCOM macro not within
specified time
V7-00
8508
Stack overflow detected
V7-00
8509
Undefined job CID received
03/02
Corrective Action
Check/replace M/F MAIN PWB,
PAGE MEMORY, and MMB.
G3M S/W bug->Replace the
software with the latest version.
Replace the G3M board.
G3M software bug → Replace the
software with the latest version.
Replace the G3M board.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace G3M
board. Replace the G3M or M/F
MAIN PWB.
G3M software bug -> Replace the
software with the latest version.
Replace G3M board.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.
2-20
V Code
Internal
code
V7-00
850A
Failure to convert physical
address into bank number
V7-00
850B
Undefined bank number
specified by BANK macro
V7-00
850C
Jumped to zero address
V7-00
8510
Attachment error in G3 main
task
V7-00
8511
Illegal status in procedural
control section task
V7-00
8512
Illegal event in procedural
control section task
V7-00
8514
Under-run or overrun at high
speed
V7-00
8515
SCM response command
timeout
V7-00
8516
Unexpected command
received from SCM
V7-00
8517
Illegal PI received from SCM M/F MAIN PWB or G3M software
CHAPTER 2 TROUBLESHOOTING
2.3 Level 2 Troubleshooting
Description
Corrective Action
G3M software bug -> Replace the
software with the latest version.
Replace G3M board.
G3M software bug -> Replace the
software with the latest version.
Replace G3M board.
G3M software bug -> Replace the
software with the latest version.
Replace G3M board.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.
M/F MAIN PWB or G3M software
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.
bug → Replace the software with
the latest version. Replace the
G3M or M/F MAIN PWB.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre pro 428

Table of Contents