X Code
Internal
Error Description
Code
X3-30
0960
(G4): In session, an error with
Date info. was found.
X3-30
0961
(G4): In session, an error with
Document reference info. was
found.
X3-30
0962
(G4): In session, an error with
Check Point reference info. was
found.
X3-30
0963
(G4): In session, an error with
Session Service Function was
found.
X3-30
0964
(G4): In session, an error is
present with instruction of Relay
boradcast, etc.
X3-30
0965
(G4): Session received an illegal
event.
X3-30
0966
(G4): Session received an invalid
data unit.
X3-30
0967
(G4): Session found lack of
indispensable parameters.
X3-30
0969
(G4): An error is present with
Session Complete Parameter.
X3-35
0978
(G4): Presentation received an
illegal event.
X3-35
0979
(G4): Wrong Format was found
with Presentation.
X3-35
097A
(G4): The received presentation
descriptor has no description of
G4FAX or FDA.
X3-35
097B
(G4): Mismatched size was
instructed to be received.
X3-35
097C
(G4): Mismatched compress
mode was instructed to be
received.
X3-35
097D
(G4): Mismatched density was
instructed to be received.
2-52
03/02
Corrective Action
Check the remote terminal.
Check the remote terminal.
Check the remote terminal.
Check the remote terminal.
Check/replace M/F MAIN PWB and
G4M PWB.
Check/replace M/F MAIN PWB and
G4M PWB.
Check the remote terminal.
Check the remote terminal.
Check the remote terminal.
Check/replace M/F MAIN PWB and
G4M PWB.
Check/replace G4M PWB.
Check the remote terminal.
Check/replace M/F MAIN PWB and
G4M PWB.
Check the remote terminal.
Check the remote terminal.
Check the remote terminal.
Check the remote terminal.
X Code
Internal
Error Description
Code
X3-35
097E
(G4): Mismatched encoding was
instructed to be received.
X3-35
097F
(G4): Mismatched slow scan
option was instructed to be
received.
X3-35
0980
(G4): Activity suspension was
received from session. (CDR)
X3-35
0981
(G4): Activity discard was
received from session. (CDD)
X3-35
0982
(G4): Connection error was
received from session. (RSSN)
X3-40
0990
(G4): When G4 main is
disconnected, data link release
can't be recognized.
X3-60
0801
Layer 1 is not ready to work.
X3-61
0820
DISC command received in
multiframe setup and timer
recovery state. Correnpondant to
Toki ERR_DISC ( 0820 )
X3-61
0821
DM (F=1) is received while
waiting for link connection, re-
connection. Correnpondant to
Toki EM_DATA_LINK ( 88C5 )
X3-61
0822
Failed to connect link. N.200
T.200 time out occurred while
waiting for link connection, re-
connection. Correspondant to
Toki EM_DATA_LINK ( 88C5 )
X3-61
0846
Received link disconnection
primitive.
X3-61
0847
T.309 time out (Link reset error)
X3-62
0802
Essential parameters (called
number, high-order layer
matching, and ICM port
specification) not in call request
command
CHAPTER 2 TROUBLESHOOTING
2.3 Level 2 Troubleshooting
Corrective Action
Check the remote terminal.
Check the remote terminal.
Check the remote terminal.
Check the remote terminal.
Check the remote terminal.
Check the line. Check/replace
G4M PWB.
Check the line. Check/replace
G4/ICM PWB.
Check network and line.
Check/replace G4/ICM PWB.
Check network and line.
Check/replace G4/ICM PWB.
Check network and line.
Check/replace G4/ICM PWB.
Check the line. Check/replace
G4/ICM PWB.
Check the line. Check/replace
G4/ICM PWB.
Check/replace M/F MAIN PWB and
G4/ICM.