Xerox WorkCentre Pro 423 Service Manual page 80

Hide thumbs Also See for WorkCentre Pro 423:
Table of Contents

Advertisement

WorkCentre Pro 423/428
X Code
Internal
Error Description
Code
X0-29
0216
DC-MF I/F Failure(DC-SYS
communication disabled)
ERR_CP_DCIF_NG
X0-29
022C
Job Error. Wrong Communication
Option Parameter
X0-29
022D
Job Error. Wrong Communication
Data Parameter
X0-29
0230
Job Error. Tel Job attempted to
open the line, but in vain.
X0-29
0231
Job Error. Tel Job attempted to
connect the line, but in vain.
X0-29
0232
Job Error. Tel Job attempted to
open Handset, but in vain.
X0-29
0233
Job Error. Tel Job attempted to
transmit dial to the line, but in
vain.
X0-29
0240
Report Job failed to produce
report files, log files, etc.
X0-29
0241
Report Job failed to open or close
report files.
X0-29
0260
ppb that manages Job can't be
read.
X0-29
0261
ppb that manages Job can't be
released.
X0-29
0280
DC I/F Failure ERR_PR_DCIF_NG Check M/F MAIN PWB and
X0-29
0281
ERR_PR_DCREAD_NG
Parameters that don't exist were
attempted to read (from DC).
2-48
03/02
Corrective Action
Check M/F MAIN PWB and
MCU/SW PWB for connections.
Replace M/F MAIN PWB or
MCU/SW PWB.
Check/replace M/F MAIN PWB,
AM, MMB, Mother Board, G4M,
G4/ICM, and NCU.
Check/replace M/F MAIN PWB,
AM, MMB, Mother Board, G4M,
G4/ICM, and NCU.
Check/replace M/F MAIN PWB,
AM, MMB, Mother Board, and
HANDSET.
Check/replace M/F MAIN PWB,
AM, MMB, Mother Board, and
HANDSET.
Check/replace M/F MAIN PWB,
AM, MMB, Mother Board, and
HANDSET.
Check/replace M/F MAIN PWB,
AM, MMB, Mother Board, and
HANDSET.
Check/replace M/F MAIN PWB,
MMB, and AM.
Check/replace M/F MAIN PWB,
MMB, and AM.
Check/replace M/F MAIN PWB,
MMB, and AM.
Check/replace M/F MAIN PWB,
MMB, and AM.
MCU/SW PWB for connections.
Replace M/F MAIN PWB or
MCU/SW PWB.
X Code
Internal
Error Description
Code
X0-29
0282
ERR_PR_DCPRM_ILLEGAL
DC message included invalid
parameters.
X0-29
0287
ERR_PR_NO_PAPER
No Paper is supplied or Tray is
not installed at Receive
Print/Report Print. (proxy
document)
X0-29
0291
Job Error: Comm. Module lock
failure in Diag Job.
X0-29
0294
Comm. Module time out in Diag
Job (except in Self Diag).
X0-29
0295
Failed to lock OA module
(ERR_DJ_OA_LOCK_UNABLE)
X0-29
0296
ERR_DJ_DCIF
DC-MF I/F Failure (Data
transmission to DC-SYS Failure)
X0-29
0297
ERR_DJ_DC_EVENTDC-SYS
Event Failure (Undefined Event
/Time out/Illegal parameter)
X0-29
0298
ERR_DJ_PWBA_NOT_EXIST
MF-SYS related boards to be
diagnosed were not installed.
X0-29
0299
Unsuccessful communication
between DC-MF
(ERR_DJ_DCSYS_NOT_EXIST)
X0-29
02E0
DC-MF I/F Failure
(ERR_PT_DCIF_NG)
X0-29
02E1
DC Message Read Error
(ERR_PT_DCREAD_NG)
CHAPTER 2 TROUBLESHOOTING
2.3 Level 2 Troubleshooting
Corrective Action
Supply paper or install the tray.
Retry. Check M/F MAIN PWB and
communication module.
Retry. Check M/F MAIN PWB and
communication module.
Check OAM board connection.
Replace OAM board.
Check M/F MAIN PWB and
MCU/SW PWB for connections.
Replace M/F MAIN PWB or
MCU/SW PWB.
Check M/F MAIN PWB and
MCU/SW PWB for connections.
Replace M/F MAIN PWB or
MCU/SW PWB.
Re-enter. Check PWBA to be
diagnosed for installation status.
Check M/F MAIN PWB and
MCU/SW PWB for connections.
Replace M/F MAIN PWB or
MCU/SW PWB.
Check M/F MAIN PWB and
MCU/SW PWB for connections.
Replace M/F MAIN PWB or
MCU/SW PWB.
Check M/F MAIN PWB and
MCU/SW PWB for connections.
Replace M/F MAIN PWB or
MCU/SW PWB.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre pro 428

Table of Contents