WorkCentre Pro 423/428
U4-6 FUSER Abnormal (BSD 10.2)
Initial Check
l Check the drawer connector (P/J12) between the FUSER
ASSY and main unit for a broken or bent pin, foreign matter,
or burn.
Cheat the FRONT DOOR INTERLOCK SW and turn the power
on.
Does the HEATER ROD light?
Y
N
Remove the FUSER ASSY.
Measure the resistance
between the drawer connector P12-1 and P12-4.
Is the resistance less than 10Ÿ?
Y
N
Replace the FUSER. (PL6.1)
Return the FUSER ASSY and turn the power on.
Is the voltage 100 VAC between the drawer connector J12-
4(+) and J12-1(-)?
Y
N
Cheat the R/H INTERLOCK SW.
Is the voltage 100 VAC between the drawer connector
J12-4(+) and J12-1(-)?
Y
N
Is the voltage 100 VAC between the POWER
UNIT J10-A1(+) and J10-A3(-)?
Y
N
Is a CHOKE COIL or cheat connector
installed to the POWER UNIT P5? (100V
model)
Y
N
Install a CHOKE COIL or cheat
connector.
Is the voltage 100 VAC between the
POWER UNIT FS-11(+) and FS-12(-)?
Y
N
Perform AC FIP.
A
B
C
D
E
2-116
03/02
A
B
C
D
E
Is the voltage 0 VDC between the POWER
UNIT J523-2(+) and GND(-)?
Y
N
Replace the POWER UNIT. (PL7.1)
Is the voltage 0 VDC between the
MCU/SW PWB J403-3(+) and GND(-)?
Y
N
Check between the MCU/SW PWB
J403-3 and POWER UNIT J523-2 for
an open wire or poor contact.
Replace the MCU/SW PWB. (PL7.2)
Check
between
the
R/HINTERLOCK SW for an open wire or poor
contact. If there is no problem, replace the R/H
INTERLOCK SW. (PL2.3)
Check the actuator at the R/H INTERLOCK SW.
Check the drawer connector (P/J12) for bad contact.
Remove the FUSER ASSY. Measure the resistance between
the drawer connector P12-A4 and P12-A5.
Is the resistance less than 20kŸ?
Y
N
Replace the FUSER. (PL6.1)
Check between the FUSER drawer connector and MCU/SW
PWB for an open wire or poor contact?
There is no problem?
Y
N
Repair an open wire or poor contact.
Check the NVM values by Chain20 Func100 and Chain20
Func101.
Are the values between 0 and 16?
Y
N
Change the NVM values. The initial values are 8.
Replace the MCU/SW PWB. (PL7.2)
CHAPTER 2 TROUBLESHOOTING
U6-1 Memory Error at POWER ON (BSD 3.1C)
If Power OFF/ON does not repair the error, replace the MCU/SW
PWB.(PL7.2)
U6-2 Memory Error at POWER ON (BSD 3.1C)
If Power OFF/ON does not repair the error, replace the MCU/SW
PWB.(PL7.2)
U6-3 Memory Error at POWER ON (BSD 3.1C)
If Power OFF/ON does not repair the error, replace the MCU/SW
PWB (PL7.2).
POWER
UNIT
and
U6-4 Memory Error at POWER ON (BSD 3.1C)
If Power OFF/ON does not repair the error, replace the MCU/SW
PWB (PL7.2).
U6-41 Memory Error at POWER ON (BSD 3.1A)
If Power OFF/ON does not repair the error, replace the IIT/IPS
PWB (PL3.1).
U6-42 Memory Error at POWER ON (BSD 3.1A)
If Power OFF/ON does not repair the error, replace the IIT/IPS
PWB (PL3.1).
U6-43 Memory Error at POWER ON (BSD 3.1A 3.1C
3.3)
If NVM initialization does not repair the error, replace MCU/SW
PWB (PL7.2), IIT/IPS PWB (PL3.1), and DIMM PWB(PL7.2) in
this order.
U6-44 Memory Error at POWER ON (BSD 3.1A 3.3)
Replace the IIT/IPS PWB (PL3.1) and DIMM PWB(PL7.2) in this
order.
U6-5 Memory Error at POWER ON (BSD 3.1C)
If Power OFF/ON does not repair, replace the MCU/SW PWB
(PL7.2).
U6-82 Memory Error at POWER ON (BSD 3.1A)
Level 2 Troubleshooting