Xerox WorkCentre Pro 423 Service Manual page 427

Hide thumbs Also See for WorkCentre Pro 423:
Table of Contents

Advertisement

WorkCentre Pro 423/428
6.1.7 System feature – Memory
1. Memory for Fax
This machine has a standard memory of 2MB embedded. Additional 8MB memory and
1GB HDD (10MB memory is necessary) are optionally available. These are used to
accumulate image information at transmission and reception.
2M memory (standard)
Memory capacity
Corresponding number of sheets storable for
Send/receive operations (Using PLATEN and SEF)
Standard
2Mbyte (MMR)
101
2Mbyte (JBIG)
129
8M memory (FXAP Standard)
Memory capacity
Send/receive operations (Using PLATEN and SEF)
Standard
10Mbyte (MMR)
590
10Mbyte (JBIG)
756
1GB HHD(OPTION)
Memory capacity
(MMR)
(JBIG)
Ref. On Send/receive operations
ITU-T No.1 Chart is used as the document. The figure indicates the number of
sheets storable before being switched to Immediate Send/Receive operation.
(Actually, over the indicated number can be sent/received by the Immediate
Send/Receive operations.) (threshold: 20%)
2. Memory for Copy
With the optional electronic sort kit (1GB HDD) added
Number of sheets sortable: 100 (A4)
Fine res.
Super fine
Super fine
(400dpi)
(600dpi)
66
37
23
84
45
29
Fine res.
Super fine
Super fine
(400dpi)
(600dpi)
369
210
131
473
259
165
Send/receive operations
960 documents max/960 pages max
Or until memory becomes full
Same as above
03/02
6-10
6.1.8 Electrical feature
1. Operational power supply
Single phase 2 wire line
Input voltage
100VAC10%
110VAC±10%(TFX)
220-240VAC±10%(FXA)
2. Power cord
To be plugged into the main processor and prepared by each Opco (exceptTFX).
3. Leakage breaker
• Leakage breaking current: 10A or below
• Leakage breaking response time: within 100msec
4. Billing Counter
• Electronic billing counter is embedded.
• Individual counter is equipped in each mode.
1) Copy counter
2) Fax counter
3) Printer counter
5. Count up is made as follows:
• Simplex copy:
1) Outputting onto the Face Down Tray
When the trail edge passes through the Fuser Exit Sensor
2) Outputting onto the Face Up Tray
When the trail edge passes through the Fuser Exit Sensor
3) Outputting onto the Finisher
When the trail edge passes through the Fuser Exit Sensor
• Duplex copy:
When the first side trail edge passes through the Fuser Exit Sensor
The second side is in the same way as Simplex copy.
• Number of Count up
Simplex copy:
Duplex copy:
Test Print (Simplex):
Transparency interleaf:
CHAPTER 6 GENERAL
6.1 Specifications
Current capacity
Frequency
15A
50/60Hz±2%
13A
60Hz±2%
7A
50/60Hz±2%
1
the first side and second side, each 1
1
0 for blank

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre pro 428

Table of Contents