Maintenance 6. Maintenance Parts Replacement Procedures
6.6.2 Switching Power Supply (75W)
Switching
(1) Turn OFF the Controller and unplug the power connector.
Power Supply
(2) Remove 3 screws (M4 pan head) and
(75W)
Removal
(3) Change the Controller's direction and put
(4) Remove 16 screws and the bottom panel.
(5) Remove Cable No. (5), (11) connecting
(6) Remove 4 screws and remove the
190
fixing plate.
the DPB down.
Bottom panel
with the Switching Power Supply
(75W).
Refer to Maintenance:
3.2 Diagram of Cable Connections.
Switching Power Supply (75W) from
the Controller.
Fixing plate
Right-side panel
RC620 Rev.8