Maintenance 5. Firmware Update
5.4 Firmware Initialization Procedure
The firmware initialization procedure described in this section.
(1) Turn ON the Controller.
(2) Shutdown the development software EPSON RC+ 6.0.
(3) Copy the content of "firmware CD-ROM" to the USB memory and insert the USB
memory to the controller USB port.
(4) Execute "Ctrlsetup60.exe".
(5) Select the <Initialize> option button and click the <Next> button.
(6) Confirm the message shown below and Click the <Next> button.
(7) Check the version information and click the <Install> button.
RC620 Rev.8
143