Setup & Operation 12. Option Slots

12.2.5 Output Circuit

Rated Output Voltage
Maximum Output Current
Output Driver
On-State Resistance (average) : 23.5 Ω or less
Two types of wiring are available for use with the nonpolar photoMOS relay in the output
circuit.
Protected Expansion I/O Board
Typical Output Circuit Application 1
64
: +12 V to 24 V ±10%
: TYP 100 mA/1 output
: PhotoMOS Relay
Expansion I/O-1
10 Output No.64
11 Output No.65
(Same)
12 Output No.66
(Same)
13 Output No.67
(Same)
14 Output No.68
(Same)
15 Output No.69
(Same)
27 Output No.70
(Same)
28 Output No.71
17 Output No.64 to 71 common (GND)
(Same)
29 Output No.72
(Same)
30 Output No.73
(Same)
Omit
33 Output No.72 to 79 common (GND)
GND
+DC
L
Load
L
RC620 Rev.8