Tp Port - Epson RC620 CU Manual

Robot controller
Hide thumbs Also See for RC620 CU:
Table of Contents

Advertisement

Setup & Operation 7. TP Port
7.

TP Port

The TP port connects the Teach Pendant to the Controller.
For the details, refer to Setup & Operation
Example
When nothing is connected to the TP port, Emergency Stop status occurs in the Controller.
When the Teach Pendant is not connected, connect the TP/OP bypass plug.
Typical cable connection
A: TP Cable A
Controller
The shape of the cable connector used in connection A differs to connection B.
TP Cable A
TP Cable B
- Do not connect TP1 to the following Robot Controllers. Connecting to the following
NOTE
Robot Controllers may result in malfunction of the device since the pin assignments are
different.
- Do not connect the following devices to the TP port of RC620. Connecting these
devices may result in malfunction of the device since the pin assignments are different.
- Be careful of the operating instructions of the TP1 when connecting it to the Robot
Controller RC180/RC170, it is different from the explanation in this manual Setup &
operation 13. Option: Teach Pendant.
When using the TP1 with the RC180/RC170, refer to the RC170 / RC180 Option Teach
Pendant.
Teach Pendant Connection
(1) Make sure the Controller and manipulator are surely connected.
(2) Connect the Teach Pendant connector to the TP port on RC620 Controller.
(3) Turn on the RC620 Controller.
Teach Pendant connection and disconnection from the Controller are allowed when the
Controller power is ON.
NOTE
When the Teach Pendant connector is removed from the Controller with the mode selector
key switch of the Teach Pendant in the "Teach" position, the operation mode will remain
in the TEACH mode. The operation mode cannot be switched to AUTO mode. Be sure
to remove the Teach Pendant after switching the operation mode to "Auto" mode.
44
TP Cable
Teach
Pendant
A
Conversion Kit CK1
: Circular connector to connect to the conversion kit CK1.
: D-sub connector to connect directly to the Controller.
RC420 / RC520 / SRC5** / SRC-3** / SRC-2**
OPTIONAL DEVICE dummy plug
Operation Pendant OP500
Operator Pendant OP500RC
13. Option: Teach Pendant.
B: TP Cable B
TP Cable
Controller
Jog Pad JP500
Teaching Pendant TP-3**
Teach
B
Pendant
RC620 Rev.8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc620 seriesRc620 du

Table of Contents