Motor Speed Error Detection
The dynamic brake circuit is activated when the system detects that the motor is running at
incorrect speed.
Positioning Overflow –Servo Error- Detection
The dynamic brake circuit is activated when the system detects that the difference between
the Manipulator's actual position and commanded position exceeds the margin of error
allowed.
Speed Overflow –Servo Error- Detection
The dynamic brake circuit is activated when the Manipulator's actual speed is detected to
mark an overflow (the actual speed is outside the nominal range) error.
CPU Irregularity Detection
Irregularity of CPU that controls the motor is detected by the watchdog timer. The system
CPU and the motor controlling CPU inside the Controller are also designed to constantly
check each other for any discrepancies. If a discrepancy is detected, the dynamic brake
circuit is activated.
Memory Check-sum Error Detection
The dynamic brake circuit is activated when a memory check-sum error is detected.
Overheat Detection at the Motor Driver Module
The dynamic brake circuit is activated when the temperature of the power device inside the
Motor Driver module is above the nominal limit.
Relay Deposition Detection
The dynamic brake circuit is activated when relay deposition, junction error, or open fault is
detected.
Over-Voltage Detection
The dynamic brake circuit is activated when the voltage of the Controller is above the normal
limit.
AC Power Supply Voltage Drop Detection
The dynamic brake circuit is activated when the drop of the power supply voltage is detected.
Temperature Anomaly Detection
The temperature anomaly is detected.
Fan Malfunction Detection
Malfunction of the fan rotation speed is detected.
RC620 Rev.8
Setup & Operation 2. Part Names and Functions