Figure 8 - Adding The Standard Telegram - Datalogic AMT58*-PN Series Instruction Manual

Profinet absolute encoders
Table of Contents

Advertisement

AMT58x-PN ProfiNET®
Now we need to choose the data length and the type of data that
should be sent to and from the IO controller, thus we need to install a
Standard Telegram. Four types of telegrams with different
characteristics are available: Standard Telegram 81, Standard
Telegram 82, Standard Telegram 83 and Standard Telegram 84. For
detailed information on the Standard Telegrams refer to the section
"7.1 Telegrams" on page 44.
For instance we need to install the Standard Telegram 83.
To do this select the desired Telegram available for the
HMx16/16384PT
module
(it
can
be
found
under
HMx16/16384PT\MULTITURN 30 bit MODULE) and drag and drop it
onto the variables table in the bottom left, as shown in the Figure.

Figure 8 - Adding the Standard Telegram

16