Figure 43- Configuring The Io Controller Topology - Datalogic AMT58*-PN Series Instruction Manual

Profinet absolute encoders
Table of Contents

Advertisement

AMT58x-PN ProfiNET®
Now you need to set a connection between the port of the controller
and the port of the encoder. Please check the specific configuration
of your Profinet network. In the example the port 2 of the IO controller
is connected to the port 1 of the IO device; see Figure 55.
So, first configure the IO controller and set its port 2 to be connected
to the port 1 of the IO device. Double click the X2 P2 R PORT 2 slot
in the CPU configuration table and open the Port 2 properties dialog
box. The Properties – PN-IO – Port 2 property sheet will appear.
Enter the Topology tabbed page and set the Port 1 (X1 P1) value in
the drop-down menu in the Partner port item of the Partners group
box. Confirm pressing the OK button.
Refer also to section "11.7 Topology Editor".

Figure 43- Configuring the IO controller topology