AMT58x-PN ProfiNET®
You have the option of establishing the reserved transmission
bandwidth for IRT data as a proportion of the maximum reservable
transmission bandwidth for cyclic user data communication. The
proportion is specified in percent (%).
In doing so, the maximum transmission bandwidth set by the system
for cyclic data may not be exceeded by the reserved transmission
bandwidth for IRT plus the transmission bandwidth that is required
for the cyclic data in the free transmission bandwidth (RT
communication).
Press the Details... button in the Domain Management dialog box.
The Details – Sync domain dialog box will appear on the screen. In
the Upper limit for IRT drop-down list available in the Cyclic data
group box, select one of the default values (in %). STEP 7 offers the
following selections: 0, 10, ... 100.

Figure 51 - Sync domain details dialog box

The PROFINET IO system of the sync domain is established now on
a send clock.
Save the settings and close both the Details – Sync Domain and the
Domain management dialog boxes pressing the OK button.
Finally save, compile and then download the configuration to the
controller.