AMT58x-PN ProfiNET®
There is no functionality of this parameter if the
Scaling function
control
parameter is disabled.
EXAMPLE
The HM58 PT Profinet encoder has a singleturn resolution of 16 bits
(65536 cpr) and a multiturn resolution of 14 bits (16384 revolutions);
the permissible value for the
Measuring units / Revolution
will be
0
16
16
between 2
and 2
(2
= 65536) while the permissible value for the
30
30
Total measuring range
will be between 2 and 2
(2
=
1073741824).
NOTE
When you change the value next to this parameter, then you are
required to enter a new preset.

Maximum Master Sign-Of-Life failures

With this parameter the number of allowed failures of the master's
sign of life is defined. The default value is one (1).
Default = 1 (min. = 1, max. = 255)
NOTE
This
parameter
is
only
supported
in
compatibility
mode
(Compatibility
mode).