15.2 Setting the preset value

NOTE
This page is designed to help you setting a Preset value easily.
Please note it allows you just to enter and save the value, not to
execute the preset. If you need to execute the preset you must set
the bit 12 (Request set/shift of home position) of the G1_STW
control word (see on page 52). Refer also to the index
P65000 – Preset value on page 62; to
page 48; and to the section "14.2 Preset diagram" on page 114.
In a customary way you should always use the asynchronous
transmission to set the preset value.
Using this page the preset value is stored automatically on the non
volatile memory (you do not need to use the parameter P971 –
Transfer to non volatile memory).
To enter a preset value please proceed as follows:
1.
open the Profinet encoder web server by typing the IP address
of the encoder you want to connect to in the address bar of
your web browser and confirm;

Figure 92 - Opening the web server

AMT58x-PN ProfiNET®
G1_XIST1 preset control
on
125