3. Mechanical installation

WARNING
Installation and maintenance operations have to be carried out by
qualified personnel only, with power supply disconnected. Shaft and
mechanical components must be in stop.
For any information on the mechanical data and the electrical
characteristics of the encoder please refer to the technical catalogue.

3.1 Solid shaft encoders

 Mount the flexible coupling 1 on the encoder shaft;
 fix the encoder to the flange 2 (or to the mounting bell) by means
of the screws 3;
 secure the flange 2 to the support (or the mounting bell to the
motor);
 mount the flexible coupling 1 on the motor shaft;
 make sure the alignment tolerances of the flexible coupling 1 are
respected.

3.1.1 Customary installation

AMT58

3.1.2 Installation using fixing clamps (code LKM-386)

AMT58
4
a [mm] b [mm] c [mm] d [mm]
36 H7
48
-
a [mm] b [mm] c [mm] d [mm]
36 H7
-
67
-
-