Sanken S06-4A005-B Instruction Manual page 98

High performance vector control multifunction inverter
Table of Contents

Advertisement

20
signal
2DF
21
3DF
signal
22
signal
5DF
23
9DF
signal
24
signal
AD2
25
AD3
signal
26
signal
JOG
27
MBS
signal
28
signal
ES
29
RST
signal
31
Positioning completion signal
32
Discharge resistor on
34
Frequency counter (output frequency) (※
1)
35
Frequency counter (command frequency)
(※1)
36
Overload alarm level setting signal
(Including when in
acceleration/deceleration )
42
signal
Torque matching
43
Low speed detection signal
47
Motor speed counter(※1)
48
Forward run detection signal(※2)
49
Reverse run detection signal(※2)
*1 Can not be used together with the current output function. When outputting frequency counter or motor speed counter, set
F1515 = 0 to disable the current output function.
*2 If only single-phase pulse is input to PG input terminal, it can not detect the direction of rotation. Therefore, the rotation
direction signal can not be correctly output.
*3 No output in torque control or position control.
F1512
Counter output multiple
This function specifies the output multiple when the inverter's output frequency, command frequency and motor speed are countered
and output to the control circuit output terminals (DO1-DO3).
Code No.
Function Name
F1512
Counter output multiple
The output multiple can be set where the inverter's frequency and command frequency counter and motor speed counter (which can be
set with F1509 - F1511) are output from multifunctional output terminals DO1 - DO3. When motor speed counter multiple in F1512 is
1, 1 rpm indicates 0.1Hz, and the motor rotation direction is output to the forward run detection signal and reverse run detection signal.
Example 1) When F1512 = 1, the frequency will be output from the control signal output terminals at 1 time the output frequency
and command frequency of the inverter. When the inverter output frequency = 60 Hz, the frequency counter output =
60 Hz.
Example 2) When F1512 = 10, the frequency will be output from the control signal output terminals at 10 times the output
frequency and command frequency of the inverter. When the inverter output frequency = 60 Hz, the frequency counter
output = 600Hz.
Example 2) When F1512 = 10, the motor speed counter outputs 1500Hz with 1500rpm. (1rpm indicates 1Hz)
● Related functions
F1509-F1511=34: Frequency counter output (output frequency)
F1509-F1511=35: Frequency counter output (command frequency)
F1509-F1511=47: Motor speed counter
Note 1: The output range of frequency counter output is 1.5-1,500Hz. When the coefficient calculation result of frequency
counter output multiple is below 1.5Hz, the output is always OFF. And, 1,500 Hz is the limit when the frequency is
above 1,500 Hz.
Note 2: Output frequency is the actual frequency output by the inverter, and may be different from command frequency
according to the load condition in vector control mode. Even in constant speed operation under the vector control
mode, if a certain frequency counter output is required, set F1509 - F1511 = 35 (command frequency).
ON if the multifunctional input terminal 2DF is on.
ON if the multifunctional input terminal 3DF is on.
ON if the multifunctional input terminal 5DF is on.
ON if the multifunctional input terminal 9DF is on.
ON if the multifunctional input terminal AD2 is on.
ON if the multifunctional input terminal AD3 is on.
ON if the multifunctional input terminal JOG is on.
ON if the multifunctional input terminal MBS is on.
ON if the multifunctional input terminal ES is on.
ON if the multifunctional input terminal RST is on.
On if position deviation is less than F8111: positioning range in position control.
ON if the discharge resistor is on.
signal
F1512: the output frequency calculated with counter output multiple.
F1512: the command frequency calculated with counter output multiple.
On when the load condition is F1704: above overload pre-alarm value.
ON when the motor torque is within the range specified by F1516: torque matching level and
F1517: torque matching range.
ON when the motor torque is within the range specified by F1518: low speed matching level
and F1519: low speed matching range.
Motor speed is output by the multiple specified by F1512: counter output multiple.
ON when the motor speed is greater than F1518: low speed matching range in forward run
direction.
ON when the motor speed is greater than F1518: low speed matching range in reverse run
direction.
1~100
- 97 -
Data Content
Setting Resolution
Factory Presets
1
1