1514
Relay 1 contact output
selection
1515
Reserved
1516
Torque matching level
1517
Torque matching range
1518
Low speed matching
level
1519
Low speed matching
range
1520
Reserved
1521
Reserved
System-related functions
1601
Copy function
1602
Changed code display
function
1603
Function lock
1604
Data initialization
1605
Reserved
1606
Reserved
1607
Reserved
1701
Output current limiting
function
1702
Electric thermal setting
1703
Output current limiting
at constant speed
43: Low speed detection signal
48:Forward run detection signal
49:Reverse run detection signal
0:Alarm contact,
1:In operation 1,
2:Undervoltage,
3:End of simple scheduled operation,
4:In operation 2,
5:Frequency matching (1st speed frequency),
6:Frequency matching (1st to 16th speed frequencies),
7:Frequency approach,
8:Overload alarm level setting signal (the value of F1704),
9:Electric thermistor pre-alarm signal ,
10:Radiator overheat pre-alarm signal,
13:Excitation and DC braking signals,
14:Lower frequency limit matching signal,
15:Upper frequency limit matching signal,
16:Servo on ready signal ,
17:Zero servo completion signal ,
18:FRsignal,
19:RRsignal,
20:2DFsignal,
21:3DFsignal,
22:5DFsignal,
23:9DFsignal,
24:AD2signal,
25:AD3signal,
26:JOGsignal,
27:MBSsignal,
28:ESsignal,
29:RSTsignal,
31:Positioning completion signal,
32:Discharge resistor on signal,
36:Overload alarm level setting signal,
42:Torque matching signal,
43: Low speed detection signal
48:Forward run detection signal
49:Reverse run detection signal
0~±200%
0~50%
0~2000rpm
0~100rpm
0:No function
1:Transfer the current code data to the operation
panel
2:Transfer the contents stored by operation panel to the inverter
(Excluding motor parameters measured )
3:Transfer the contents stored by operation panel to the inverter
(Including motor parameters measured )
0:No function
1:Display differences from factory preset
2:Display differences from user's initial value
0:Code data changeable(No lock function)
1:Code data unchangeable (except F1603)
2:Code data (except frequency setting-related) unchangeable
(except F1603, F1021, F2101 — F2116)
3:Code data unchangeable (except F1603 and function codes
using communication)
0:No function
1:Initialize factory presets
2:Invalid parameter by auto tuning
3:Initialize user's data
99:Set user's initial value
A MODEL
B MODEL
0:No function
20~105%
0:No function
- 51 -
0:No function
50~200%
0:No function
50~150%
1
0
0.1 %
100
0.1 %
25
1rpm
100
1rpm
10
1
0
1
0
1
0
1
0
1%
150
120
1%
100
1
0

Hide quick links: